Migration From xJARiD/MeshCore¶
This page covers migrating from the previous firmware published at:
https://github.com/xJARiD/MeshCore
to the EastMesh firmware published at:
https://github.com/xJARiD/MeshCore-EastMesh
These steps are intended for existing repeater users moving to the new EastMesh *_repeater_mqtt firmware.
Start by downloading the correct EastMesh release for your board from:
Before You Start¶
- you can flash the new firmware without erasing first
- after flashing, you will need to reapply your Wi-Fi and some MQTT settings
- you can do this either from the serial CLI or from the companion app
Required Setup After Flashing¶
Once the new firmware is flashed, set:
set wifi.ssid <your-ssid>set wifi.pwd <your-password>set mqtt.iata <code>set mqtt.status on
Optional Settings¶
If you were previously using owner metadata, also set:
set mqtt.owner <64-hex-char-public-key>set mqtt.email <email>
If you had previously disabled TX publishing, also set:
set mqtt.tx off
Final Step¶
Once the settings are applied:
reboot
After reboot, the repeater should be operational.
Verify Operation¶
Confirm the repeater is up and connected with:
get wifi.statusget mqtt.status
Validate In The Web Console¶
If the web panel is enabled on your board, you can also verify through the local HTTPS admin page.
Enable and check it with:
set web onget web.status
Then open:
https://<IP_ADDRESS>/
Notes:
- ignore the browser warning for the self-signed certificate
- log in with the admin password
- this is the same admin password used for admin access via the companion app
Legacy MQTT Commands¶
Some MQTT CLI commands from the previous firmware do not apply in EastMesh and should not be migrated.
EastMesh stores its current Wi-Fi and MQTT uplink settings separately from the older firmware, so older broker and analyzer settings do not carry forward in a useful way. After flashing, re-enter the settings you still use now, rather than expecting the old MQTT bridge configuration to map across.
These previous MQTT CLI commands no longer apply in EastMesh:
get mqtt.serverget mqtt.portget mqtt.passwordget mqtt.analyzer.usget mqtt.analyzer.euget mqtt.config.valid
If you flash without erase first, some old values may still remain in flash in the background. The important point is that EastMesh does not use those old MQTT bridge values for its current uplink configuration, so users should not expect them to carry forward or have any effect.
Recommended Migration Flow¶
- Flash the new EastMesh firmware without erasing.
- Open the serial CLI or companion app.
- Set
wifi.ssid,wifi.pwd,mqtt.iata, andmqtt.status on. - Optionally set
mqtt.ownerandmqtt.email. - If you previously had TX publishing disabled, set
mqtt.tx off. - Reboot the repeater.
- Verify with
get wifi.statusandget mqtt.status. - Optionally confirm local web access with
set web on,get web.status, andhttps://<IP_ADDRESS>/.
Related Docs¶
Last Resort¶
If the repeater still does not come up cleanly after reflashing, reapplying settings, and rebooting, the last resort is to perform a full erase-flash and then configure it again from scratch.